Resultado da pesquisa (10)

Termo utilizado na pesquisa Echocardiography

#1 - Echocardiographic features of pre- and postcapillary pulmonary hypertension with a focus on the right ventricle in dogs

Abstract in English:

Pulmonary hypertension (PH) in dogs is a syndrome that can occur secondary to several causes, including left heart disease (postcapillary) and chronic respiratory disease (precapillary). This study evaluates morphological and functional consequences in the right ventricle (RV) of dogs with pre- and postcapillary PH through echocardiography, and also considers the severity of PH (mild, moderate or severe). Echocardiography was performed on 66 dogs of various breeds and weights (age >3 years old) which were assigned to three groups: postcapillary PH, which included mitral valve disease/endocardiosis, precapillary PH, which included chronic respiratory diseases (bronchitis, collapse of the trachea and primary lung cancer or metastasis), and finally, a healthy group of controls. The parameters for RV morphology were RV1, RV2, and RV3 for systole and diastole. The following measurements were used to assess RV systolic function: tricuspid annular plane systolic excursion (TAPSE), TAPSE:Ao (aorta), maximum velocity of the tricuspid systolic wave obtained by tissue Doppler (S’), S’:Ao, right ventricle end-diastolic area (RVEDA); RVEDA:BSA (body surface area); flow velocity integral (FVI) and FVI:Ao. The variables were assessed using ANOVA. The results showed that RV3d, RV1s, S’:Ao, S’, and FVI were able to distinguish cases of pre- and postcapillary PH in this study. Remodeling of the RV of dogs with PH was observed, which can be influenced by the pre- or postcapillary origin of the PH, with dilation in dogs with postcapillary PH and severe PH. The results for RV systolic function were similar, with FVI and FVI:Ao showing that RV ejection function is reduced in dogs with postcapillary PH and with severe PH.

Abstract in Portuguese:

A hipertensão pulmonar (HP) em cães é uma síndrome que pode ocorrer secundária às diversas causas, dentre elas, a doença cardíaca esquerda (pós-capilar) e a doença respiratória crônica (pré-capilar). Essa é uma condição importante que motivou os objetivos do estudo: avaliar ecocardiograficamente as consequências morfológicas e funcionais no ventrículo direito (VD) dos cães acometidos com HP pré- e pós-capilar, considerando também o estágio de severidade da HP (leve, moderada ou severa). A ecocardiografia foi realizada em 66 cães de diversas raças e pesos, com pelo menos quatro anos de idade, que compuseram um grupo com doença valvar mitral, ou endocardiose, outro com doença respiratória crônica (bronquite, colapso de traqueia e neoplasia pulmonar primária ou metástase), e por último, um grupo saudável. Os parâmetros para a morfologia do VD foram RV1, RV2 e RV3 na sístole e na diástole. Para a avaliação da função sistólica do VD foram mensurados: excursão sistólica do plano anular tricúspide (TAPSE), TAPSE:Ao (aorta), velocidade máxima da onda sistólica da tricúspide obtida pelo doppler tecidual (S’), S’:Ao, área do ventrículo direito no final da diástole (RVEDA); RVEDA:BSA (body superficie area); integral tempo velocidade (FVI) e FVI:Ao. As variáveis foram avaliadas por meio da ANOVA. Os resultados mostraram que RV3d, RV1s, S’:Ao, S’ e FVI foram capazes de distinguir casos de HP pré e pós-capilar neste estudo. Observou-se que há remodelamento do VD de cães com HP e este pode ser influenciado pela origem pré ou pós-capilar da HP, encontrando-se dilatado em cães com HP pós capilar e com HP severa. Os resultados para a função sistólica do VD foram similares, uma vez que o FVI e FVI:Ao mostraram que a capacidade de ejeção do VD está reduzida nos cães com HP pós-capilar e com HP severa.


#2 - Evaluation of left atrial function in asymptomatic dogs with chronic myxomatous mitral valve disease: twodimensional feature-tracking echocardiography and Simpson’s monoplanar methods

Abstract in English:

The present study evaluated the volume and function of the left atrium by two-dimensional echocardiographic feature-tracking imaging (2D-FTI) and Simpson’s monoplanar modeling in dogs with asymptomatic degenerative mitral valve disease (DMVD). The study consisted of 80 dogs that were divided into the following three groups: Group 1, 21 dogs (A); Group 2, 30 dogs (B1) and Group 3, 29 dogs (B2). The variable strain (contraction phase) was significantly lower in Group 3 than in Group 1 (12.92±4.54 x 16.69±5.74, p=0.014), and significant differences in the contraction strain index (CSI) were observed between all of the groups that were evaluated (1 = 46.82±8.10, 2 = 39.88±8.03, 3 = 35.25±5.64, p<0.0001). The atrial diastolic volume index (AdVi) that was measured by 2D-FTI was significantly higher in Group 3 than in Group 1 (1.31±0.95 x 0.96±0.31, p=0.038), and the atrial cardiac index (ACI) was also higher in Group 3 than in Group 1 (102.38±80.18 x 78.19±33.38, p=0.030). Atrial function was assessed by Simpson’s monoplanar method, which demonstrated an increase in the left atrial systolic volume, while the contractile function decreased with an increasing disease severity (Group 1 0.21±0.06; Group 2 0.25±0.06; Group 3 0.32±0.08, p<0.0001). The intraobserver and interobserver assessments showed low to moderate variability; most of the values for the coefficient of variation for the variables that were analysed with each method were below 25%. Thus, DMVD was determined to cause an alteration in atrial function, especially in the contraction phase, and even in asymptomatic animals, and the methods of 2D-FTI echocardiography and Simpson’s monoplanar evaluation are sensitive and early methods for the detection of left atrial dysfunction.

Abstract in Portuguese:

O presente estudo avaliou o volume e a função atrial esquerda obtidos por meio da ecocardiografia bidimensional feature tracking (2D-FTI) e pelo método monoplanar de Simpson em cães saudáveis e cães com DMVD assintomáticos. Foram avaliados 80 cães distribuídos em três grupos: Grupo 1, 21 cães (classe A); Grupo 2, 30 cães (classe B1) e Grupo 3, 29 cães (classe B2). A variável strain (fase de contração) foi significativamente menor no Grupo 3 que no Grupo 1 (12,92±4,54 x 16,69±5,74, p=0,014) e para a variável índice de strain de contração (CSI), houve diferença estatística entre todos os grupos avaliados (1 = 46,82±8,10; 2 = 39,88±8,03; 3 = 35,25±5,64, p<0,0001). O índice de volume diastólico atrial (iVdA) mensurado por meio do 2D-FTI foi significativamente maior no Grupo 3 que no Grupo 1 (1,31±0,95 x 0,96±0,31, p=0,038), assim como para o índice cardíaco atrial (iCA) também foi maior no Grupo 3 (102,38±80,18 x 78,19±33,38, p=0,030). A função atrial avaliada pelo método monoplanar de Simpson demonstrou um aumento do volume atrial esquerdo e do volume sistólico do átrio esquerdo, enquanto que a função contrátil diminuiu com o aumento da gravidade da doença (Grupo 1 0,21±0,06; Grupo 2 0,25±0,06; Grupo 3 0,32±0,08; p<0,0001). A avaliação intraobservador e interobservador, demonstrou variabilidade baixa a moderada, uma vez que a maioria dos valores de coeficiente de variação se concentraram abaixo de 25% para as variáveis analisadas em ambos os métodos. Dessa forma, conclui-se que a DMVD causa alteração na função atrial, principalmente na fase de contração, mesmo em animais assintomáticos e que a ecocardiografia 2D-FTI e o método monoplanar de Simpson são métodos sensíveis e precoces na detecção da disfunção atrial esquerda.


#3 - Echocardiographic parameters and vertebral heart size (VHS) in lambs during the neonatal period, 38(9):1869-1877

Abstract in English:

ABSTRACT.- Ulian C.M.V., Lourenço M.L.G., Inamassu L.R., Souza P.M., Mamprim M.J., Alfonso A. & Chiacchio S.B. 2018. Echocardiographic parameters and VHS in lambs during the neonatal period. [Parâmetros ecocardiográficos e tamanho cardíaco vertebral (VHS) em cordeiros durante o período neonatal.] Pesquisa Veterinária Brasileira 38(9):1869-1877. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Rua Prof. Doutor Walter Mauricio Correa s/n, Distrito de Rubião Júnior, Botucatu, SP 18618-681 Brazil. E-mail: mege@fmvz.unesp.br Devido à imaturidade cardíaca, os recém-nascidos apresentam uma morfologia e débito cardíacos diferenciados quando comparado aos adultos. O objetivo deste estudo foi descrever as alterações cardíacas ecocardiográficas e silhueta cardíaca ao exame radiográfico a partir do método VHS (vertebral heart size) em cordeiros recém-nascidos durante o período neonatal. Vinte e oito cordeiros saudáveis da raça Ile de France foram avaliados desde o nascimento até os 35 dias de idade. Ao exame ecocardiográfico avaliou-se em sístole e diástole, os índices relacionados aos ventrículos direito (VD) e esquerdo (VE), a parede livre do ventrículo esquerdo, aorta (Ao), átrio esquerdo (Ae), septo e ponto E, e diâmetros finais. Foi feita a relação entre o átrio esquerdo e aorta, além da fração de ejeção e de encurtamento. O VHS foi mensurado a partir do tamanho dos eixos longo e curto do coração em relação às vértebras torácicas. Os resultados obtidos demonstraram aumento do VE em relação ao VD no decorrer dos 35 dias (p<0,05). Os índices calculados e a relação AE:Ao não tiveram diferença. Os valores de VHS tiveram distribuição normal com média de 9,67 vértebras em todo o período. Os parâmetros radiográficos e ecocardiográficos mostraram diferenças significativas entre os momentos analisados. Os valores VHS variaram de 8.4 a 11.2 vertebras. Para evitar que essas alterações sejam erroneamente interpretadas como cardiopatias na espécie, este estudo demonstra às peculiaridades do desenvolvimento cardíaco neonatal em cordeiros, além de descrever parâmetros para esta faixa etária em cordeiros da raça Ilê de France.

Abstract in Portuguese:

RESUMO.- Ulian C.M.V., Lourenço M.L.G., Inamassu L.R., Souza P.M., Mamprim M.J., Alfonso A. & Chiacchio S.B. 2018. Echocardiographic parameters and VHS in lambs during the neonatal period. [Parâmetros ecocardiográficos e tamanho cardíaco vertebral (VHS) em cordeiros durante o período neonatal.] Pesquisa Veterinária Brasileira 38(9):1869-1877. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Rua Prof. Doutor Walter Mauricio Correa s/n, Distrito de Rubião Júnior, Botucatu, SP 18618-681 Brazil. E-mail: mege@fmvz.unesp.br Due to cardiac immaturity, newborns have a different morphology and cardiac output when compared with adults. The purpose of this study was to describe the cardiac changes in echocardiographic characteristics and vertebral heart size (VHS) in newborn lambs during the neonatal period. Twenty-eight healthy Ile de France lambs were evaluated from birth to 35 days old. With the assistance of echocardiography, this study evaluated, both in systole and diastole, indexes related to the right and left ventricles, the aorta (Ao), the left atrium (LA), the E point to septal separation (EPSS) and the thickness of the interventricular septum (VSd, VSs). The left atrium-to-aorta ratio (LA:Ao) was analyzed and both the shortening (SF%) and ejection fractions were calculated (EF%). The VHS was obtained by measuring the heart’s long and short axes and comparing it to the thoracic vertebrae. Throughout the first 35 days, the results obtained demonstrated an increased LV:RV ratio when compared to adult lambs. The calculated indexes and the LA:Ao ratio did not present statistically significant differences. The VHS values were normally distributed, presenting a mean of 9.67 vertebrae (v) during the entire period. Both radiographic and echocardiographic parameters showed significant differences between the analyzed moments. The VHS values ranged from 8.4v at the minimum end to 11.2v at the maximum. In order to prevent these changes from being misdiagnosed as heart diseases, this study contributed to take note of neonatal physiological anatomy peculiarities and in addition, it describes the parameters for this age in Ilê de France lambs.


#4 - Doppler echocardiography in goats Moxotó

Abstract in English:

This study describes the two-dimensional echocardiographic sections, M-mode cardiac dimensions, and Doppler flow indices in Moxotó goats. A total of 32 Moxotó goats were divided into four equal groups (n = 8) according to body weight class: G1 (5-10 kg), G2 (10-15kg), G3 (15-20kg) and G4 (>20kg). All animals underwent echocardiographic tests, two-dimensional and M-mode, and pulsed (PW), continuous (CW) and color flow (CF) Doppler. The spectral formation of echocardiographic images was satisfactory, although some adjustments were necessary to obtain adequate cuts/sections for goats above 20 kg. One-dimensional echocardiographic parameters (IVSD, IVSS, LVIDd, LVIDs, VPWd, LVPWs) and cardiac function index (EF and FS) showed a positive descriptive correlation with body weight in the categories studied. The septal separation of point E was constant among the weight categories investigated, ranging from 0.1 to 0.41cm. The Em/Am ratio was predominantly “>1”, with Emax> Amax in all weight categories, and not affected by the heart rate among the studied weight classes. The IVRT was also uniform among the studied weight classes. The individual flow rates of the aortic valve were higher than the maximum flow rate of the pulmonary valve. The ejection times of the aortic and pulmonary flows were positively correlated with increasing body weight, something also observed on the VTI of flow spectra, given the direct relationship of this variable with the stroke volume inversely to FC. The acceleration time (AT) of pulmonary blood flow was greater than the aortic flow, and directly related to increasing body weight and inversely with heart rate. Thus, the standardization of Doppler echocardiographic variables in goats, should always consider breed, age and body weight as well as repeatability and reproducibility studies and adoption of individual reference elements for reliable development of normal values.

Abstract in Portuguese:

Objetivou-se com este estudo reportar descrições acerca dos cortes ecocardiográficos no modo bidimensional, das dimensões cardíacas pelo modo unidimensional e dos índices de fluxo Doppler em caprinos da raça Moxotó. Foram utilizados 32 caprinos da raça Moxotó, distribuídos em quatro grupos por categoria de peso corporal, de igual número (n=8), em: G1 (5-10kg), G2 (10-15kg), G3 (15-20kg) e G4 (>20kg). Todos foram submetidos a um registro ecocardiográfico pelos modos bidimensional, modo-M, Doppler pulsado (PW), contínuo (CW) e de fluxo de cores (CF). A formação espectral das imagens ecocardiográficas foi satisfatória, contudo algumas adaptações foram necessárias para obtenção adequada dos cortes nos caprinos acima de 20 kg. Os parâmetros ecocardiográficos em modo unidimensional (IVSd, IVSs, LVIDd, LVIDs, VPWd, LVPWs) e índices de função cardíaco (EF e FS) apresentaram uma correlação descritiva positiva com peso corporal enquadradas nas categorias estudadas. A separação septal do ponto E, mostrou-se constante dentre as categorias de peso investigadas, variando entre 0,1 a 0,41cm em caprinos da raça Moxotó. A relação Em/Am foi predominantemente “ >1” em todos os caprinos estudados, com Emax > Amax em todas as categorias, não sendo sujeito a influência da frequência cardíaca dentre as categorias de peso estudados. O mesmo pode ser aplicado ao TRIV, que se mostrou uniforme dentre os intervalos de peso estudados. As velocidades de fluxo da valva aórtica individuais foram superiores a velocidade máxima do fluxo da valva pulmonar. Os tempos de ejeção dos fluxos aórtico e pulmonar apresentaram correlação positiva descritiva com o aumento do peso corporal. Condição também observada sobre o VTI dos espectros de fluxo, dada a relação direta desta variável com o volume sistólico inversamente à FC. O tempo de aceleração (TA) do fluxo pulmonar foi superior ao fluxo aórtico, sendo este relação direta com aumento do peso corporal por categoria estudada e inversamente à frequência cardíaca. Desta forma, a padronização das variáveis ecodopplercardiográficas na espécie caprina, deve sempre considerar particularidades relacionadas ao padrão racial, faixa etária e peso corporal, bem como estudos de repetibilidade e reprodutibilidade e adoção de elementos individuais referenciais para elaboração confiável de valores de normalidade.


#5 - Echocardiographic indexes and dimension in horses of the Mangalarga Marchador breed, 36(6):533-538

Abstract in English:

ABSTRACT.- Latorre S.M., Bonomo C.C.M., Michima L.E.S., Hagen S.C.F. & Fernandes W.R. 2016. [Echocardiographic indexes and dimension in horses of the Mangalarga Marchador breed.] Índices e dimensões ecocardiográficas de equinos da raça Mangalarga Marchador. Pesquisa Veterinária Brasileira 36(6):533-538. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: carolina.bonomo@usp.br Aiming to establish the echocardiographic reference values of cardiac dimensions and indexes in horses of the Mangalarga Marchador breed, 80 horses, weighing 320 to 500 kg, that were divided in four group by gender and age, as follows: 1.6 to 4-year-old females (G1), more than 4-year-old females (G2), 1.6 to 4-year-old males (G3) and above 4-year-old males (G4), were evaluated by standardized technique. The evaluation consisted of B-mode and guided M-mode echocardiography, by which the following measurements were made: from the right cardiac window, by B- and M-mode: systolic and diastolic RVID, IVS, LVID, LVFW, Aod, FS% and EF%, by B-mode: Las, Aod, and Las/Aod, by M-mode: S-E point, from left cardiac window, by B- and M-mode: LVIDs, LVIDd, FS% and EF% and by B-mode: Las. There were statistic differences between means of the four groups for the following parameters: Aod, Las, RVIDs, RVIDd, IVSs, IVSd, LVIDs, LVIDd, LVFWs, LVFWd, Vs, Vd. There were statistic correlations between Aod, Las, IVSs, IVSd, LVFWs, LVFWd, Vd and age; Aod, Las, IVs, IVSd, LVIDd, LVFWs, Las/Aod and bodyweight and thoracic perimeter; and Aod, LAs, IVSs, IVSd, LVIDs, LVFWs, Vd and height. Sex and age group influenced the reference values for the Mangalarga Marchador horses; males above 4 years presented higher ventricular measurement values. Height, weight and age of the horses influenced in the same way the results, all being positively related to the size of the cardiac structure.

Abstract in Portuguese:

RESUMO.- Latorre S.M., Bonomo C.C.M., Michima L.E.S., Hagen S.C.F. & Fernandes W.R. 2016. [Echocardiographic indexes and dimension in horses of the Mangalarga Marchador breed.] Índices e dimensões ecocardiográficas de equinos da raça Mangalarga Marchador. Pesquisa Veterinária Brasileira 36(6):533-538. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: carolina.bonomo@usp.br Com o objetivo de determinar os valores de referência ecocardiográficos de equinos da raça Mangalarga Marchador, foram avaliados 80 equinos desta raça, machos e fêmeas, com 1,6 a 16 anos de idade, pesando entre 320 a 500 kg, divididos igualmente em 4 grupos: fêmeas de 1,6 a 4 anos de idade (G1), fêmeas com mais de 4 anos de idade (G2), machos de 1,6 a 4 anos de idade (G3), machos com mais de 4 anos de idade (G4). A avaliação constou de exame ecocardiográfico mono e bidimensional, tendo sido realizados através da janela cardíaca direita, nos modos B e M: DIVDs, DIVDd, SIVs, SIVd, DIVEs, DIVEd, PLVEs, PLVEd, Aod, FS%, EF%, AEs, Aod, Aes/ Aod, ponto E-S. Através da janela cardíaca esquerda nos modos B e M: DIVEs, DIVEd, FS%, EF%, AEs. Foram observadas diferenças estatísticas entre as médias dos quatro grupos dos seguintes parâmetros: Aod, AEs, DIVDs, DIVDd, SIVs, SIVd, DIVEs, DIVEd, PLVEs, PLVEd, Vs, Vd e correlações estatísticas positivas entre Aod, AEs, SIVs, SIVd, PLVEs, PLVEd, Vd e a idade, entreAod, AEs, SIVs, SIVd, DIVEd, PLVEs, AEs/Aod e o peso e o perímetro torácico e entre Aod, AEs, SIVs, SIVd, DIVEs, PLVEs, Vd e a altura da cernelha. Houve influência tanto do sexo como da faixa etária sobre os valores de referência para equinos da raça Mangalarga Marchador, tendo os machos acima de 4 anos apresentados valores de medidas ventriculares maiores. O peso, altura e idade dos animais influenciaram da mesma forma os resultados, estando todos relacionados positivamente ao tamanho da estrutura cardíaca.


#6 - Echocardiographic evaluation of cardiac development of athletic horses: comparision between different physical activities, 34(9):923-927

Abstract in English:

ABSTRACT.- Bonomo C.C.M., Michima L.E.S., Miyashiro P. & Fernandes W.R. 2014 [Echocardiographic evaluation of cardiac development of athletic horses: comparision between different physical activities.] Avaliação ecocardiográfica do desenvolvimento cardíaco de cavalos atletas: comparação entre atividades físicas distintas. Pesquisa Veterinária Brasileira 34(9):923-927. Departamento de Clínica Médica,, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: carolinabonomo@yahoo.com.br The aerobic capacity of equine athletes may be explained, in part, by its cardiac development associated with physical training. Echocardiographic examination of equine athletes allows the visualization of these changes and cardiac function of these animals. We aimed to evaluate echocardiographically horses of different sports to see if the type of physical activity performed by each group of animals promotes structural or functional cardiac differences. 196 horses underwent echocardiography at rest were divided into three groups: Polo group, 44 horses participating in tests of Polo; QM group, 49 horses of Quarter Horse, participants of barrel and pole bending events and PSI group, 103 horses of the breed Thoroughbred racehorses. We evaluated the following heart rates: IVS, LVD and LVFW in systole and diastole, LA in systole, Ao in diastole, mean LA: Ao, EF, EV, LVFSV, LVFDV, FS%, E-S, LVET, CO and HR. The PSI group animals showed higher left ventricular volumes and provided proportionately less efficiency when we analyzed EV. Animals in group Polo and QM showed higher values when variables such as cardiac function. The more intense physical activity performed by the animals of group QM and Polo provided better functional development of the heart of these animals, and the PSI group, presented figures suggesting that aerobic capacity can still be better exploited through better targeting of their physical training.

Abstract in Portuguese:

RESUMO.- Bonomo C.C.M., Michima L.E.S., Miyashiro P. & Fernandes W.R. 2014 [Echocardiographic evaluation of cardiac development of athletic horses: comparision between different physical activities.] Avaliação ecocardiográfica do desenvolvimento cardíaco de cavalos atletas: comparação entre atividades físicas distintas. Pesquisa Veterinária Brasileira 34(9):923-927. Departamento de Clínica Médica,, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: carolinabonomo@yahoo.com.br A capacidade aeróbica dos equinos atletas pode ser explicada, em partes, pelo seu desenvolvimento cardíaco associado ao treinamento físico. O exame ecocardiográfico de equinos atletas permite a visualização destas alterações e da função cardíaca destes animais. Buscou-se avaliar ecocardiograficamente equinos de diferentes modalidades esportivas, para verificar se o tipo de atividade física desempenhada por cada grupo de animais promove diferenças estruturais ou funcionais cardíacas. 196 equinos foram submetidos à avaliação ecocardiográfica em repouso, sendo divididos em três grupos: grupo Polo, 44 equinos participantes de provas de Polo; grupo QM, 49 equinos da raça Quarto de Milha, participantes de provas de baliza e tambor, e grupo PSI, 103 equinos da raça Puro Sangue Inglês participantes de provas de corridas. Foram avaliados os seguintes índices cardíacos: SIV, DIVE e PLVE em sístole e diástole, AE em sístole, Ao em diástole, relação AE:Ao, FEj, VEj, VSFVE, VDFVE, FS%, E-S, TEVE, DC e FC. Os animais do grupo PSI apresentaram os maiores volumes de ventrículo esquerdo, tendo apresentado proporcionalmente menor eficiência quando analisado o VEj. Os animais do grupo Polo e QM apresentaram melhores valores quando analisadas as variáveis de função cardíaca. A atividade física mais intensa desempenhada pelos animais do grupo QM e Polo permitiu melhor desenvolvimento funcional do coração destes animais, tendo o grupo PSI, apresentado valores que sugerem que sua capacidade aeróbica ainda pode ser melhor explorada através de melhor orientação de seu treinamento físico.


#7 - Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation, 34(3):290-300

Abstract in English:

ABSTRACT.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br Hypertrophic cardiomyopathy (HCM) is the most common feline heart disease and is characterized by increased cardiac mass with a hypertrophied nondilated left ventricle. Myocardial dysfunction occurs in cats with HCM but less is known about dysfunctions in initial stages of HCM. A mutation in MYBPC-A31P gene has been identified in a colony of Maine Coon cats with HCM. However, the close correlation between genotype and phenotype still be inconclusive. Myocardial analysis by tissue Doppler imaging (TDI) is a noninvasive echocardiographic method to assess systolic and diastolic function that is more sensitive than conventional echocardiography. To evaluate diastolic and systolic function in cats with mutation, with or without ventricular hypertrophy, Maine Coon cats (n=57) were screened for mutation and examined with both echocardiography and TDI (pulsed tissue Doppler and color tissue Doppler methods). Then, were phenotypically classified in: normal (n=45), suspects (n=7) and HCM group (n=5); and genotypically classified in: negative (n=28), heterozygous (n=26) and homozygous group (n=3). Myocardial velocities (by pulsed and color tissue Doppler imaging) measured in the basal and mildventricular segment of the interventricular septal wall (IVS), left ventricular free wall (LVW), left ventricular anterior wall (LVAW), left ventricular posterior wall (LVPW) and radial segment of LVW, was compared among different groups. A decreased longitudinal Em velocities (pulsed tissue Doppler) at the mildventricular segment of LVW was observed in HCM cats compared with suspects and normal cats. A decreased longitudinal Em/Am (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. A significant increased longitudinal E/Em (color tissue Doppler) at the basal segment of IVS was observed in HCM cats compared with suspects and normal cats. And a significant decreased longitudinal Sm (color tissue Doppler) at the basal segment of the LVW was observed in heterozygous cats compared with negative cats, both without hypertrophy. There was a positive correlation between summated early and late diastolic velocities (Em/Am) and heart rate; and a positive correlation between Sm and Em velocities and heart rate, both in pulsed and in color TDI. TDI analyses are a new, valuable and reproducible method in cats that alone is not able to identify cats with mutation before myocardial hypertrophy. Despite high expectations regarding the use of TDI for early identification of individuals with HCM, there is still need for larger studies with greater numbers of individuals.

Abstract in Portuguese:

RESUMO.- Pellegrino A., Daniel A.G.T., Pereira G.G., Júnior F.F.L., Itikawa P.H. & Larsson M.H.M.A. 2014. [Assessment of diastolic function by pulsed and color tissue Doppler echocardiography in Maine Coon cats tested for MyBPC-A31P mutation.] Avaliação da função diastólica por meio de Doppler tecidual pulsado e colorido em gatos da raça Maine Coon geneticamente testados para a mutação no gene MyBPC-A31P. Pesquisa Veterinária Brasileira 34(3):290-300. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP, 05508-270, Brazil. E-mail: arinepel@yahoo.com.br A cardiomiopatia hipertrófica (CMH) é a principal cardiopatia dos felinos e é caracterizada por hipertrofia miocárdica concêntrica, sem dilatação ventricular. Disfunções miocárdicas ocorrem em gatos com CMH, mas pouco se conhece a respeito destas alterações nos estágios iniciais da afecção. Em gatos da raça Maine Coon, a mutação no gene MyBPC-A31P está relacionada com a CMH de origem familial, porém, a correlação exata entre o genótipo e o fenótipo ainda é inconclusiva. A ecocardiografia tecidual é uma modalidade não invasiva que permite avaliação da função miocárdica e é mais sensível que a ecocardiografia convencional. Para avaliar as funções sistólica e diastólica, antes ou após a ocorrência de hipertrofia ventricular, gatos da raça Maine Coon (n=57), geneticamente testados para a mutação, foram avaliados por meio de ecocardiografias convencional e tecidual (nas modalidades Doppler tecidual pulsado e Doppler tecidual colorido). Posteriormente, foram fenotipicamente classificados em: normais (n=45), suspeitos (n=7) e acometidos pela CMH (n=5); e genotipicamente classificados em: negativos (n=28), heterozigotos (n=26) e homozigotos para a mutação (n=3). Valores de velocidades miocárdicas (Doppler tecidual pulsado e colorido) medidos na região basal e média do septo interventricular (SIV), da parede livre do ventrículo esquerdo (PVE), da parede anterior do ventrículo esquerdo (PAVE), da parede posterior do ventrículo esquerdo (PPVE) e do segmento radial da PVE, foram comparados nos diferentes grupos. Observou-se que as velocidades longitudinais Em (Doppler tecidual pulsado) na região média da PVE foram menores nos gatos com CMH quando comparados com suspeitos e normais. Os valores de Em/Am (Doppler tecidual colorido), na região basal do SIV, foram inferiores nos gatos com CMH quando comparados com suspeitos e normais. A relação E/Em (Doppler tecidual colorido), na região basal do SIV, foi maior nos gatos com CMH em relação aos suspeitos e normais, enquanto que os valores de Sm (Doppler tecidual colorido), em região basal da PVE, foram menores nos gatos heterozigotos quando comparados com os negativos, ambos sem hipertrofia ventricular. Observou-se correlação positiva entre a ocorrência de fusão das ondas Em e Am e a frequência cardíaca, assim como correlação positiva entre valores de Sm e Em e a frequência cardíaca (Doppler tecidual pulsado e colorido). A ecocardiografia tecidual é uma nova modalidade ecocardiográfica reprodutível em gatos que, isoladamente, não permite diferenciar gatos portadores da mutação antes do desenvolvimento de hipertrofia ventricular. Apresenta utilidade como auxílio no diagnóstico em fases iniciais, mas, apesar da expectativa para a identificação precoce de indivíduos portadores da CMH, ainda há necessidade de estudos mais extensos e com maior número de indivíduos.


#8 - Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf, 32(12):1336-1340

Abstract in English:

ABSTRACT.- Mantovani M.M., Silva A.C., Muzzi R.A.L., Oberlender G., Resende R.M., Muzzi L.A.L., Lacreta Junior A.C.C. & Nogueira R.B. 2012. Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf. Pesquisa Veterinária Brasileira 32(12):1336-1340. Setor de Clínica Médica de Pequenos Animais, Serviço de Cardiologia Veterinária, Departamento de Medicina Veterinária, Universidade Federal de Lavras, Campus Universitário s/n, Caixa Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: adrianagudi@gmail.com The measurement of cardiovascular features of wild animals is important, as is the measurement in pets, for the assessment of myocardial function and the early detection of cardiac abnormalities, which could progress to heart failure. Speckle tracking echocardiography (2D STE) is a new tool that has been used in veterinary medicine, which demonstrates several advantages, such as angle independence and the possibility to provide the early diagnosis of myocardial alterations. The aim of this study was to evaluate the left myocardial function in a maned wolf by 2D STE. Thus, the longitudinal, circumferential and radial strain and strain rate were obtained, as well as, the radial and longitudinal velocity and displacement values, from the right parasternal long axis four-chamber view, the left parasternal apical four chamber view and the parasternal short axis at the level of the papillary muscles. The results of the longitudinal variables were -13.52±7.88, -1.60±1.05, 4.34±2.52 and 3.86±3.04 for strain (%), strain rate (1/s), displacement (mm) and velocity (cm/s), respectively. In addition, the radial and circumferential Strain and Strain rate were 24.39±14.23, 1.86±0.95 and -13.69±6.53, -1.01±0.48, respectively. Thus, the present study provides the first data regarding the use of this tool in maned wolves, allowing a more complete quanti&#64257;cation of myocardial function in this species.

Abstract in Portuguese:

RESUMO.- Mantovani M.M., Silva A.C., Muzzi R.A.L., Oberlender G., Resende R.M., Muzzi L.A.L., Lacreta Junior A.C.C. & Nogueira R.B. 2012. Strain and strain rate by two- dimensional speckle tracking echocardiography in a maned wolf. Pesquisa Veterinária Brasileira 32(12):1336-1340. Setor de Clínica Médica de Pequenos Animais, Serviço de Cardiologia Veterinária, Departamento de Medicina Veterinária, Universidade Federal de Lavras, Campus Universitário s/n, Caixa Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: adrianagudi@gmail.com A obtenção de parâmetros cardiovasculares em animais selvagens são importantes de serem avaliados, assim como em animais de companhia, para a obtenção da função miocárdica e determinação precoce de alterações cardíacas que poderiam evoluir para insuficiência cardíaca . A ecocardiografia speckle tracking (2D STE) é uma ferramenta nova que tem sido utilizada em medicina veterinária, a qual tem demonstrado várias vantagens quanto ao seu uso, como a independência do ângulo de insonação e a possibilidade de se obter o diagnóstico precoce de alterações miocárdicas. Objetivou-se avaliar a função miocárdica esquerda de um lobo guará por meio do uso da 2D STE. Desta forma, foram obtidas as variáveis Strain e Strain Rate longitudinais, circunferenciais e radiais, assim como a velocidade e o deslocamento longitudinais e radiais, utilizando os cortes eixo longo paraesternal direito quatro câmaras, paraesternal esquerdo apical quatro câmaras e eixo curto paraesternal direito no plano dos músculos papilares. Os resultados das variáveis longitudinais fora -13,52±7,88, -1,60±1,05, 4,34±2,52 e 3,86±3,04 para Strain (%), Strain rate (1/s), deslocamento (mm) e velocidade (cm/s), respectivamente. Quanto ao Strain e Strain rate radiais e circunferenciais foram obtidos 24,39±14,23, 1,86±0,95 e -13,69±6,53, -1,01±0,48. Portanto, o presente estudo fornece os primeiros dados a respeito do uso desta ferramenta em lobos guarás, permitindo uma quantificação da função miocárdica de forma mais completa nesta espécie.


#9 - Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs, 30(7):586-592

Abstract in English:

ABSTRACT.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com This study evaluated aortic (AO) and pulmonary (Pul) valves flow with pulsed-wave Doppler by qualitative (presence of valvar insufficiency and characteristic of flow profile) and quantitative analysis, and the following echocardiographic parameters were obtained: peak (PV) and mean (MV) velocities, velocity-time integral (VTI), acceleration (AT) and ejection (ET) time. Thirty dogs were studied, and to be considered normal, physical, laboratory, electrocardiographic, echocardiographic (uni and bidimensional mode) exams, thoracic radiography, and measurement of the blood pressure were accomplished, and the following echocardiographic parameters were obtained: AO PV= 1.22±19.38m/s; AO MV= 0.72±0.08m/s; AO VTI= 0.14±0.02m; AO AT= 38.80±11.29ms; AO ET= 197.90±24.77ms; Pul PV= 0.95±0.18m/s; Pul MV= 0.63±0.10m/s; Pul VTI= 0.13±0.02m; Pul AT= 70.97±18.87ms; Pul ET= 203.70±28.98ms. Heart rate presented negative correlation with AO VTI, AO ET, Pul VTI, Pul AT, Pul ET, and the variable weight had positive correlation with AO VTI, AO AT, AO ET, Pul VTI, Pul ET, differently from the gender, that had no influence on the evaluated parameters. The comparison of aortic and pulmonary valves flow demonstrated AO PV and AO MV higher than Pul PV and Pul MV, respectively, AO VTI higher than Pul VTI, and Pul AT higher than AO AT.

Abstract in Portuguese:

RESUMO.- Petrus L.C., Oliveira V.M.C., Pereira G.G. & Larsson M.H.M.A. 2010. [Evaluation of aortic and pulmonary valves flow with pulsed-wave Doppler echocardiography in healthy dogs.] Avaliação dos fluxos das valvas aórtica e pulmonar com ecocardiografia Doppler pulsátil em cães clinicamente sadios. Pesquisa Veterinária Brasileira 30(7):586-592. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Professor Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lilipetrus@hotmail.com Avaliaram-se com Doppler pulsátil os fluxos das valvas aórtica (AO) e pulmonar (Pul) por meio de análise qualitativa (presença de regurgitações valvares e características do espectro avaliado) e quantitativa, com obtenção de parâmetros ecocardiográficos como velocidades máxima (V. Max.) e média (V. Me.), integral de velocidade (VTI), tempo de aceleração (TA) e ejeção (TE), de 30 cães considerados clinicamente sadios por meio de exames físico, laboratoriais, eletrocardiográfico, ecocardiográfico (modos uni e bidimensional), radiográfico de tórax e mensuração da pressão arterial sistêmica. Obtiveram-se os seguintes resultados para os referidos parâmetros: V.max. AO= 1,22±19,38m/s; V. Me. AO= 0,72±0,08m/s; VTI AO= 0,14±0,02m; TA AO= 38,80±11,29ms; TE AO= 197,90±24,77ms; V. Max. Pul= 0,95±0,18m/s; V. Me. Pul= 0,63±0,10m/s; VTI Pul= 0,13±0,02m; TA Pul= 70,97±18,87ms; TE Pul= 203,70± 28,98ms. Em apenas três animais observou-se regurgitação pulmonar. Alguns parâmetros apresentaram correlação negativa com a variável freqüência cardíaca (VTI AO, TE AO, VTI Pul, TA Pul, TE Pul); outros correlação positiva com a variável peso (VTI AO, TA AO, TE AO, VTI Pul, TE Pul,) e não se observou influência da variável sexo na maioria dos parâmetros avaliados. Na comparação entre os dois fluxos, observaram-se V. Max. AO e V. Me. AO maiores que V. Max. Pul. e V. Me. Pul., respectivamente, VTI AO maior que VTI Pul, e TA AO menor que TA Pul.


#10 - Avaliação ecocardiográfica em bezerros da raça Holandesa, p.481-486

Abstract in English:

ABSTRACT.- Michima L.E.S., Leal M.L.R., Bertagnon H.G., Fernandes W.R. & Benesi F.J. 2007. [Echocardiographic evaluation in Holstein calves.] Avaliação ecocardiográfica em bezerros da raça Holandesa. Pesquisa Veterinária Brasileira 27(12):481-486. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, Bloco 12/14, São Paulo, SP 05508-270, Brazil. E-mail: lilianm@usp.br With the purpose of establishing echocardiographic measurements in Holstein calves, 25 calves, 8 to 28 days of age and body weight ranging from 27 to 57 kg, were used. The echocardiographic examination was proceeded in B and M-modes to obtain the following parameters, in diastole and systole: right ventricle (2.05±0.13cm and 1.59±0.13cm) and left ventricle internal diameter (3.91±0.09cm and 2.52±0.13cm), and interventricular septum (1.24±0.04cm and 1.62±0.06cm) and left ventricle free wall thickness (0.92±0.04cm and 1.50±0.05cm). The values for both left and right atria in systole were 2.97±0.12cm and 4.110.21cm, respectively. The left diastolic (67.90±3.65ml), systolic (25.32±3.05ml) and ejection (42.58±2.46ml) volumes, cardiac output (3857±339ml/min), aortic root diameter (2.52±0.05cm), E-point septal separation (0.65±0.08cm), left ventricle ejection time (0.39±0.02s), fractional shortening (36.27±2.40%) and ejection fraction (64.67±3.22%) were also calculated. There was a mean positive linear correlation (66.4%, P<0.01) between the aortic root diameter and the bodyweight, mean negative linear correlation (P<0.01) heart rate (69.1%) and cardiac output (62.4%). There was a tendency of the calves in between the left ventricle ejection time and presenting a smaller left chamber diameter, although maintained the relationship between myocardial wall thickness and functional indexes.

Abstract in Portuguese:

ABSTRACT.- Michima L.E.S., Leal M.L.R., Bertagnon H.G., Fernandes W.R. & Benesi F.J. 2007. [Echocardiographic evaluation in Holstein calves.] Avaliação ecocardiográfica em bezerros da raça Holandesa. Pesquisa Veterinária Brasileira 27(12):481-486. Departamento de Clínica Médica, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, Bloco 12/14, São Paulo, SP 05508-270, Brazil. E-mail: lilianm@usp.br With the purpose of establishing echocardiographic measurements in Holstein calves, 25 calves, 8 to 28 days of age and body weight ranging from 27 to 57 kg, were used. The echocardiographic examination was proceeded in B and M-modes to obtain the following parameters, in diastole and systole: right ventricle (2.05±0.13cm and 1.59±0.13cm) and left ventricle internal diameter (3.91±0.09cm and 2.52±0.13cm), and interventricular septum (1.24±0.04cm and 1.62±0.06cm) and left ventricle free wall thickness (0.92±0.04cm and 1.50±0.05cm). The values for both left and right atria in systole were 2.97±0.12cm and 4.110.21cm, respectively. The left diastolic (67.90±3.65ml), systolic (25.32±3.05ml) and ejection (42.58±2.46ml) volumes, cardiac output (3857±339ml/min), aortic root diameter (2.52±0.05cm), E-point septal separation (0.65±0.08cm), left ventricle ejection time (0.39±0.02s), fractional shortening (36.27±2.40%) and ejection fraction (64.67±3.22%) were also calculated. There was a mean positive linear correlation (66.4%, P<0.01) between the aortic root diameter and the bodyweight, mean negative linear correlation (P<0.01) heart rate (69.1%) and cardiac output (62.4%). There was a tendency of the calves in between the left ventricle ejection time and presenting a smaller left chamber diameter, although maintained the relationship between myocardial wall thickness and functional indexes.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV