Abstract in English:
ABSTRACT.- Kawamoto F.Y.K., Muzzi L.A.L., Liria B.O.A.G., Camassa J.A.A., Moreira S.H., Rossignoli P.P. & Muzzi R.A.L. 2017. [Magnetic resonance in the evaluation of autogenous osteochondral graft in articular cartilage of rabbits.] Ressonância magnética na avaliação de enxerto osteocondral autógeno na cartilagem articular de coelhos. Pesquisa Veterinária Brasileira 36(5):502-510. Departamento de Medicina Veterinária, Universidade Federal de Lavras, Câmpus Universitário, Av. Doutor Sylvio Menicucci 1001, Cx. Postal 3037, Kennedy, Lavras, MG 37200-000, Brazil. E-mail: fe.kawamoto@gmail.com
This study aimed to determine the characteristics and applicability of magnetic resonance imaging (MRI) in the evaluation of autogenous osteochondral graft in intact or macerated format, with or without insulin-like growth factor type 1 (IGF-1) used in repair of cartilage lesions induced in rabbits. Nine New Zealand rabbits were used, in which 18 stifle joints underwent grafting procedure in the femoral trochlear groove. These were divided into four groups, referred as intact osteochondral graft + IGF-1 (n=5), intact osteochondral graft + saline solution (n=4), macerated osteochondral graft + IGF-1 (n=5) and macerated osteochondral graft + saline solution (n=4). Animals were euthanized 12 weeks after surgery and the joints were subjected to MRI using a high magnetic field scanner of 1.5 Tesla. In addition, samples of grafting sites were subjected to anatomopathological examination. The MRI was effective as a noninvasive method to evaluate the repair tissue in osteochondral grafts in articular cartilage of the femur of rabbits by providing complementary data to macroscopic and histological examinations. Through these images and anatomopathological examinations satisfactory results were observed in relation to the repair process of autogenous osteochondral grafts in cartilage of rabbits, regardless of its format or the addition of IGF-1.
Abstract in Portuguese:
RESUMO.- Kawamoto F.Y.K., Muzzi L.A.L., Liria B.O.A.G., Camassa J.A.A., Moreira S.H., Rossignoli P.P. & Muzzi R.A.L. 2017. [Magnetic resonance in the evaluation of autogenous osteochondral graft in articular cartilage of rabbits.] Ressonância magnética na avaliação de enxerto osteocondral autógeno na cartilagem articular de coelhos. Pesquisa Veterinária Brasileira 36(5):502-510. Departamento de Medicina Veterinária, Universidade Federal de Lavras, Câmpus Universitário, Av. Doutor Sylvio Menicucci 1001, Cx. Postal 3037, Kennedy, Lavras, MG 37200-000, Brazil. E-mail: fe.kawamoto@gmail.com
Este trabalho teve o objetivo de determinar as características e a aplicabilidade do exame de ressonância magnética na avaliação de enxerto ostecondral autógeno, em formato íntegro ou macerado, associado ou não ao fator de crescimento semelhante à insulina tipo 1 (IGF-1), utilizado no reparo de lesões induzidas na cartilagem articular de coelhos. Foram utilizados 9 coelhos da linhagem Nova Zelândia, em que as 18 articulações fêmoro-tíbio-patelares foram submetidas à enxertia osteocondral autógena no sulco troclear femoral. Estas foram divididas em quatro grupos, denominados como enxerto osteocondral íntegro + IGF-1 (n=5), enxerto osteocondral íntegro + solução fisiológica (n=4), enxerto osteocondral macerado + IGF-1 (n=5) e enxerto osteocondral macerado + solução fisiológica (n=4). Os animais foram eutanasiados em 12 semanas após a cirurgia e as articulações foram submetidas ao exame de ressonância magnética utilizando um aparelho scanner de 1,5 Tesla de alto campo magnético. Além disso, amostras dos locais de enxertia foram submetidas aos exames anatomopatológicos. O exame de ressonância magnética mostrou-se eficaz como um método não invasivo para avaliação do tecido de reparação em enxertos osteocondrais na cartilagem articular do fêmur de coelhos, fornecendo dados complementares aos exames macroscópicos e histológicos. Por meio destas imagens e dos exames anatomopatológicos, foram observados resultados satisfatórios em relação ao processo de reparação dos enxertos osteocondrais autógenos na cartilagem de coelhos, independentemente de seu formato ou da adição de IGF-1.
Abstract in English:
ABSTRACT.- Hage M.C.F.N.S., Iwasaki M., Rabbani S.R., Kamikawa L., Cervantes H.J.R., Bombonato P.P., Sterman F.A. & Otaduy M.C.G. 2010. [Magnetic resonance imaging in the investigation of canine heads.] Imagem por ressonância magnética na investigação da cabeça de cães. Pesquisa Veterinária Brasileira 30(7):593-604. Departamento de Veterinária, Universidade Federal de Viçosa, Av. P.H. Rolfs s/n, Viçosa, MG 36570-000, Brazil. E-mail: crishage@ufv.br
Magnetic resonance imaging (MRI) is the most sensitive method of diagnostic imaging to evaluate soft tissues, specially the brain, however it is expensive. The method is based on the nuclear magnetic resonance phenomenon that occurs when atomic nucleus with magnetic proprieties in the body are submitted to a strong magnetic field, and excited with radio frequency generating a radio frequency signal captured by a receptive antenna. The signal is processed by Fourier Transform for the image formation. This study had the objective to obtain 10 complete exams of heads in cadavers of normal dogs to MRI and to make an Atlas of head structures. The images were obtained with a magnetic resonance unit Gyroscan S15/HP Philips using a magnetic field of 1,5Tesla. The cadavers were positioned with the head into a human head coil and submitted to sagittal slices used to plan transverse and dorsal slices in T1, T2 and DP spin-echo sequences. In T1 we adjusted TR=400ms and TE=30ms, in T2 TR=2000ms and TE=80ms and in DP TR=2000ms and TE=30ms. The slice thickness was 4mm, the number of averages 2, the matrix 256x256, the factor 1,0 and the field of view 14cm. The duration of the complete exam of the head was 74,5minutes. The images obtained with the described sequences and with the human head coil was of good quality. In T1 fat was hyperintense and fluid was hypointense. In T2 fat was less hyperintense and fluid was hyperintense. The cortical bone and the air were hypointense in all sequences used because of the low proton density. The DP sequence showed the best contrast between white and gray matter when compared with T2 and T1 sequences. Distinction of cerebral sulcus and gyrus was possible because T2 showed the cerebrospinal fluid. The identification of bone structures that compound the region, muscles, main venous and arterial vessels and structures of the central nervous system, besides elements of the digestory and respiratory systems and structures of the eyes among others was possible through contrast obtained with MRI. In this study the MRI acquired in T1, DP and T2 were complementary for the anatomic study of the head and been able to demonstrate the structures of the canine head with rich anatomic details. The time used to do the complete exam of the head is compatible with the use in live animals since properly anesthetized and controlled. We had opened a way for the study of live animals and for the beginning of disease investigation, mainly that of neurologic origin because this technique is excellent for brain visualization.
Abstract in Portuguese:
RESUMO.- Hage M.C.F.N.S., Iwasaki M., Rabbani S.R., Kamikawa L., Cervantes H.J.R., Bombonato P.P., Sterman F.A. & Otaduy M.C.G. 2010. [Magnetic resonance imaging in the investigation of canine heads.] Imagem por ressonância magnética na investigação da cabeça de cães. Pesquisa Veterinária Brasileira 30(7):593-604. Departamento de Veterinária, Universidade Federal de Viçosa, Av. P.H. Rolfs s/n, Viçosa, MG 36570-000, Brazil. E-mail: crishage@ufv.br
A imagem por ressonância magnética (IRM) é o método de diagnóstico por imagem não invasivo mais sensível para avaliar as partes moles, particularmente o encéfalo, porém trata-se de uma técnica onerosa. O método fundamenta-se no fenômeno da ressonância magnética nuclear que ocorre quando núcleos atômicos com propriedades magnéticas presentes no corpo são submetidos a um campo magnético intenso, sendo posteriormente excitados por energia de radiofrequência e gerando, por sua vez, um sinal de onda de radiofrequência capaz de ser captado por uma antena receptora, passando por um processo matemático, chamado Transformada de Fourier, para posterior formação da imagem. Esse estudo objetivou realizar 10 exames completos da cabeça em cadáveres de cães normais à IRM e confeccionar um Atlas com as estruturas identificadas. As imagens foram adquiridas em um aparelho de ressonância magnética Gyroscan S15/HP Philips com campo magnético de 1,5Tesla. Os cadáveres foram posicionados com a cabeça no interior de uma bobina de cabeça humana e foram submetidos a cortes iniciais sagitais a partir de onde se planejou os cortes transversais e dorsais nas sequências de pulso spin-eco T1, T2 e DP. Em T1 utilizou-se TR=400ms e TE=30ms, T2 utilizou-se TR=2000ms e TE=80ms e na DP utilizou-se TR=2000ms e TE=30ms. A espessura do corte foi de 4mm, o número de médias foi igual a 2, a matriz foi de 256x256, o fator foi igual a 1,0 e o campo de visão foi de 14cm. A duração do exame completo da cabeça foi de 74,5minutos. As imagens obtidas com as sequências utilizadas e com a bobina de cabeça humana foram de boa qualidade. Em T1 a gordura tornou-se hiperintensa e o líquido hipointenso. Em T2 a gordura ficou menos hiperintensa e o líquido hiperintenso. A cortical óssea e o ar foram hipointensos em todas as sequências utilizadas devido a baixa densidade de prótons. A sequência DP mostrou o melhor contraste entre a substância branca e cinzenta quando comparada a T2 e a T1. T2 evidenciou o líquido cefalorraquidiano tornando possível a distinção dos sulcos e giros cerebrais. Através do exame de IRM foi possível, pelo contraste, identificar as estruturas ósseas componentes da arquitetura da região, músculos, grandes vasos venosos e arteriais e estruturas do sistema nervoso central, além de elementos do sistema digestório, respiratório e estruturas dos olhos entre outras. Nesse estudo as IRM adquiridas nas sequências T1, DP e T2 foram complementares para o estudo dos aspectos anatômicos da cabeça de cães demonstrando-os com riqueza de detalhes. O tempo requerido para o exame completo da cabeça é compátivel para uso em animais vivos desde que devidamente anestesiados e controlados. Os resultados obtidos por esse trabalho abrem caminho em nosso meio, para o estudo de animais vivos e para o início da investigação de doenças, principalmente as de origem neurológica, visto ser esta técnica excelente para a visibilização do encéfalo.