Resultado da pesquisa (14)

Termo utilizado na pesquisa fratura

#11 - Estudo crítico do tratamento de 196 casos de fratura diafisária de rádio e ulna em cães, p.371-374

Abstract in English:

ABSTRACT.- Ferrigno CRA., Schmaedecke A., Pantané C., Baccarin D.C.B. & Silveira L.M.G. 2008. [A critical study about the treatment of 196 cases of diphiseal radial and ulnar fractures in dogs.] Estudo crítico do tratamento de 196 casos de fratura diafisária de rádio e ulna em cães. Pesquisa Veterinária Brasileira 28(8):371-374. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: cassioaf@usp.br The results from three osteosynthesis methods in cases of proximal, mid and distal fractures of radio and ulna in dogs were compared: the skeletal external fixation, plates and screws and the external immobilization. Shaft fractures of radius and ulna in dogs are frequent among the orthopedic morbid cases in Veterinary Medicine and their treatment deserves special attention, due to the high number of unsuccessful cases observed. The demographic data with reference to distribution and classification of fractures, as well as the method used for osteosynthesis and its consequences, were tabulated and the data were statistically compared. As results, from the 196 fractures observed, patients with up to 6.0 kilograms were the most affected (46.4%) with lesions mainly in the distal third (64.93% of the fractures). Animals that have been operated with smaller interval between the fracture occurrence and the surgery showed better results. There was a significant difference between osteosynthesis by external fixators and screwed plates when compared to external immobilization, independent on the fracture site.

Abstract in Portuguese:

ABSTRACT.- Ferrigno CRA., Schmaedecke A., Pantané C., Baccarin D.C.B. & Silveira L.M.G. 2008. [A critical study about the treatment of 196 cases of diphiseal radial and ulnar fractures in dogs.] Estudo crítico do tratamento de 196 casos de fratura diafisária de rádio e ulna em cães. Pesquisa Veterinária Brasileira 28(8):371-374. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-900, Brazil. E-mail: cassioaf@usp.br The results from three osteosynthesis methods in cases of proximal, mid and distal fractures of radio and ulna in dogs were compared: the skeletal external fixation, plates and screws and the external immobilization. Shaft fractures of radius and ulna in dogs are frequent among the orthopedic morbid cases in Veterinary Medicine and their treatment deserves special attention, due to the high number of unsuccessful cases observed. The demographic data with reference to distribution and classification of fractures, as well as the method used for osteosynthesis and its consequences, were tabulated and the data were statistically compared. As results, from the 196 fractures observed, patients with up to 6.0 kilograms were the most affected (46.4%) with lesions mainly in the distal third (64.93% of the fractures). Animals that have been operated with smaller interval between the fracture occurrence and the surgery showed better results. There was a significant difference between osteosynthesis by external fixators and screwed plates when compared to external immobilization, independent on the fracture site.


#12 - Estudo da biomecânica oclusal e da aderência da resina acrílica auto-polimerizável (polimetilmetacrilato) em fraturas de rinoteca de tucanos (Ramphastos toco), p.335-340

Abstract in English:

ABSTRACT.- Fecchio R.S., Gomes M.S., Kolososki J., Petri B.S.S., Rossi Jr J.L. & Gioso M.A. 2008. [Study of the occlusion biomechanics and adherence of acrylic resin (polimetilmetacrilate) in fractures of rhinotheca in toucans (Ramphastos toco).] Estudo da biomecânica oclusal e da aderência da resina acrílica auto-polimerizável (polimetilmetacrilato) em fraturas de rinoteca de tucanos (Ramphastos toco). Pesquisa Veterinária Brasileira 28(7):335-340. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Prof. Dr. Orlando de Marques de Paiva 87, Bloco 8 superior, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: rfecchio@gmail.com Traction effort was applied perpendicularly to the axis of toucan beaks and for accomplishment of the essay a dynamometer was used. The beak was completely fractured when submitted to traction of 270.40 N. For fixation of the fractured beaks acrylic resin was applied using a strip of 2.0cm of width. The second beak presented resistance up to 69.75 N. The third beak was submitted to acid conditioning and resisted to force of 63.29 N. Other two new tests were accomplished the whole surface of the rhinotheca filled out. The fourth beak was not submitted to the acid attack and it resisted up to 134.40 N, and the fifth was submitted to the acid etch and it resisted up to 101.50 N. The present work did not observe statistical correlation and, consequently, differences among the procedures with previous use of acid attack and those without the use of the same.

Abstract in Portuguese:

ABSTRACT.- Fecchio R.S., Gomes M.S., Kolososki J., Petri B.S.S., Rossi Jr J.L. & Gioso M.A. 2008. [Study of the occlusion biomechanics and adherence of acrylic resin (polimetilmetacrilate) in fractures of rhinotheca in toucans (Ramphastos toco).] Estudo da biomecânica oclusal e da aderência da resina acrílica auto-polimerizável (polimetilmetacrilato) em fraturas de rinoteca de tucanos (Ramphastos toco). Pesquisa Veterinária Brasileira 28(7):335-340. Departamento de Cirurgia, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Prof. Dr. Orlando de Marques de Paiva 87, Bloco 8 superior, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: rfecchio@gmail.com Traction effort was applied perpendicularly to the axis of toucan beaks and for accomplishment of the essay a dynamometer was used. The beak was completely fractured when submitted to traction of 270.40 N. For fixation of the fractured beaks acrylic resin was applied using a strip of 2.0cm of width. The second beak presented resistance up to 69.75 N. The third beak was submitted to acid conditioning and resisted to force of 63.29 N. Other two new tests were accomplished the whole surface of the rhinotheca filled out. The fourth beak was not submitted to the acid attack and it resisted up to 134.40 N, and the fifth was submitted to the acid etch and it resisted up to 101.50 N. The present work did not observe statistical correlation and, consequently, differences among the procedures with previous use of acid attack and those without the use of the same.


#13 - Avaliação do uso de haste bloqueada e bloqueio transcortical no reparo de fraturas diafisárias de fêmur em felino, p.201-206

Abstract in English:

ABSTRACT.- Romano L., Ferrígno C.R.A., Ferraz,V.C.M. Della Nina M., Ito K.C. 2008. [Evaluation of the use of interlocking nail and transcortical blockade for the repair of diaphyseal fractures of the femur in cats.] Avaliação do uso de haste bloqueada e bloqueio transcortical no reparo de fraturas diafisárias de fêmur em felinos. Pesquisa Veterinária Brasileira 28(4):201-206. Departamento de Cirurgia do Hospital Veterinário, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lromano@usp.br Interlocking nails allow rigid fracture stabilization and present biomechanical advantages when compared to other immobilization techniques. It acts along the central mechanical axis of the bone and preserves biological concept standards for osteosynthesis. The use of interlocking nail in cats is limited because the intramedullary space is relatively small for the available nail sizes. We reported 10 cases of cats that had simple or multiple closed fractures of the femoral diaphysis. The animals weighed 3.5 to 5 kg , which allowed using nails of 4.0mm and 4.7mm in diameter. For the nail insertion, retrograde and normograde routs were used, and four 2mm titanium screws were used to lock all the perforations. No trans-surgical complication occurred, however, due to a new trauma, one of the animals suffered femoral neck fracture and transversal distal fracture to the nail, three days after surgery. Radiographies were made up to four months after surgery, and in most cases secondary bone formation was seen, showing bone consolidation in 61-89 days, excluding the animal who suffered new trauma, who presented bone healing in 150 days. Clinically, occasional lameness occurred; however, except for the animal that had new trauma, all animals initiated adequate limb support in 3 to 8 days after surgery. In conclusion, the use of 4.0mm and 4.7mm interlocking nails in felines was adequate, with bone healing in all cases, and also return of good limb function after surgery.

Abstract in Portuguese:

ABSTRACT.- Romano L., Ferrígno C.R.A., Ferraz,V.C.M. Della Nina M., Ito K.C. 2008. [Evaluation of the use of interlocking nail and transcortical blockade for the repair of diaphyseal fractures of the femur in cats.] Avaliação do uso de haste bloqueada e bloqueio transcortical no reparo de fraturas diafisárias de fêmur em felinos. Pesquisa Veterinária Brasileira 28(4):201-206. Departamento de Cirurgia do Hospital Veterinário, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Avenida Prof. Dr. Orlando Marques de Paiva 87, São Paulo, SP 05508-270, Brazil. E-mail: lromano@usp.br Interlocking nails allow rigid fracture stabilization and present biomechanical advantages when compared to other immobilization techniques. It acts along the central mechanical axis of the bone and preserves biological concept standards for osteosynthesis. The use of interlocking nail in cats is limited because the intramedullary space is relatively small for the available nail sizes. We reported 10 cases of cats that had simple or multiple closed fractures of the femoral diaphysis. The animals weighed 3.5 to 5 kg , which allowed using nails of 4.0mm and 4.7mm in diameter. For the nail insertion, retrograde and normograde routs were used, and four 2mm titanium screws were used to lock all the perforations. No trans-surgical complication occurred, however, due to a new trauma, one of the animals suffered femoral neck fracture and transversal distal fracture to the nail, three days after surgery. Radiographies were made up to four months after surgery, and in most cases secondary bone formation was seen, showing bone consolidation in 61-89 days, excluding the animal who suffered new trauma, who presented bone healing in 150 days. Clinically, occasional lameness occurred; however, except for the animal that had new trauma, all animals initiated adequate limb support in 3 to 8 days after surgery. In conclusion, the use of 4.0mm and 4.7mm interlocking nails in felines was adequate, with bone healing in all cases, and also return of good limb function after surgery.


#14 - Estudo comparativo entre as osteossínteses com placas e osteossínteses com placas associadas a enxertos de proteína morfogenética óssea (Gen-Techâ) em fraturas distais de rádio-ulna em cães com menos

Abstract in English:

ABSTRACT.- Ferrigno C.R.A.,Della Nina M.I. & Fantoni D.T. 2007. [A comparative study of osteosynthesis with plates and plates associated with grafts of bone morphogenic proteins (Gen-Techâ) in distal radio-ulna fractures in dogs with less than 6 quilograms.] Estudo comparativo entre as osteossínteses com placas e osteossínteses com placas associadas a enxertos de proteína morfogenética óssea (Gen-Techâ) em fraturas distais de rádio-ulna em cães com menos de 6 quilos. Pesquisa Veterinária Brasileira 27(2):65-69. Departamento de Cirurgia do Hospital Veterinário, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900. E-mail: cassioaf@usp.br It is well known that bone morphogenic proteins (BMP) cause osteogenesis, yet clinical research must be performed in order to really show their benefits. Animals weighing less than 6 kg show well known difficulties regarding radius and ulna fracture repair mainly with bone non-union, due to poor vascularization of the distal portion of the radius. Therefore this study aimed to compare the velocity of bone callus formation in the treatment of fracture repair with plates and screws alone or with plates and screws plus BMP. Thirty three dogs with radius and ulna fractures were distributed into two groups, where animals of the control group received the conservative treatment performed with screws and plates alone, whilst the other group received the conservative treatment and BMP. The time of bone callus formation was evaluated comparatively through radiographic exams 30, 60, 90, 120, 180 and 210 days after the surgical procedure. Animals treated with BMP showed a healing time of 32±15 days, which was significantly different (p <0.001) from the control group which required 127±34 days. With the results obtained, it can be concluded that the distal radio-ulna fractures of dogs weighing less than 6 kg suffered a significant reduction of the bone callus formation time, which was around 90 days.

Abstract in Portuguese:

ABSTRACT.- Ferrigno C.R.A.,Della Nina M.I. & Fantoni D.T. 2007. [A comparative study of osteosynthesis with plates and plates associated with grafts of bone morphogenic proteins (Gen-Techâ) in distal radio-ulna fractures in dogs with less than 6 quilograms.] Estudo comparativo entre as osteossínteses com placas e osteossínteses com placas associadas a enxertos de proteína morfogenética óssea (Gen-Techâ) em fraturas distais de rádio-ulna em cães com menos de 6 quilos. Pesquisa Veterinária Brasileira 27(2):65-69. Departamento de Cirurgia do Hospital Veterinário, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, São Paulo, SP 05508-900. E-mail: cassioaf@usp.br It is well known that bone morphogenic proteins (BMP) cause osteogenesis, yet clinical research must be performed in order to really show their benefits. Animals weighing less than 6 kg show well known difficulties regarding radius and ulna fracture repair mainly with bone non-union, due to poor vascularization of the distal portion of the radius. Therefore this study aimed to compare the velocity of bone callus formation in the treatment of fracture repair with plates and screws alone or with plates and screws plus BMP. Thirty three dogs with radius and ulna fractures were distributed into two groups, where animals of the control group received the conservative treatment performed with screws and plates alone, whilst the other group received the conservative treatment and BMP. The time of bone callus formation was evaluated comparatively through radiographic exams 30, 60, 90, 120, 180 and 210 days after the surgical procedure. Animals treated with BMP showed a healing time of 32±15 days, which was significantly different (p <0.001) from the control group which required 127±34 days. With the results obtained, it can be concluded that the distal radio-ulna fractures of dogs weighing less than 6 kg suffered a significant reduction of the bone callus formation time, which was around 90 days.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV